Meeting No.10: BigBite Optics Calibration #3
Current BigBite Optics Matrix:
[matrix]
t 1 0 0 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
y 1 0 0 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
p 1 0 0 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
D 0 0 0 -0.0292416 -0.9033330 1.81944000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
D 1 0 0 3.43311000 -9.7937800 11.4550000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
D 2 0 0 15.5068000 -50.202100 -23.181100 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
D 3 0 0 26.7883000 -66.026900 0.00000000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
T 0 0 0 0.01067500 -0.4968080 -0.1145100 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
T 1 0 0 0.49109200 0.12139600 -0.4243960 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
P 0 0 1 1.00000000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
Y 0 0 0 0.03528600 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
Y 0 1 0 0.99801300 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
Y 0 0 1 -2.8008400 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
Y 0 1 1 -0.6388680 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00
DB_run.dat Problem
I believe that BigBite information in the DB_run.dat file are not correct. BigBite scattering
angle is set to -74deg, although bigbite was positioned at -74deg during Ay and -75deg during
e'd. The central momentum of the BigBite also needs to be set. At the moment I set it to 0.5GeV/c
which approximately corresponds to the correct setting according to NIKHEF BigBite paper. At 518A
the field inside the BigBite is 0.92T and the central momentum is 0.5GeV/c
Scattering angle issue
Halog states that for runs at the beginning of our run period (e.g. #1518) BigBite
was positioned at 71deg. This is right in the middle of the elastic peak. However,
when I compare the "BB.tr.ph" variable with the phi angle of the "q"-vector rotated into
the BB-coordinate system, thing do not match if I consider 71deg as a central scattering
angle. Things get much more consistant, when I assume, that BB was positioned at 74deg.
Please see figures below. This suggests that BB was never at 71deg.
BigBite Collimator
BigBite Collimator Technical Drawing: BBCollimator.pdf
BigBite collimator reconstruction using current BB optics matrix:
"BB.tr.x" vs. "BB.tr.th" plots:
Plot without any cuts:
1st Reconstruction Model:
This plots shows which regions in focal plane correspond to different momenta. In this model
I used second order polynomials in both theta and x to reconstruct delta.
2nd Reconstruction Model:
This plots shows which regions in focal plane correspond to different momenta. In this model
I used second order polynomials in theta and linear functions in x to reconstruct delta.
3rd Reconstruction Model:
This plots shows which regions in focal plane correspond to different momenta. In this model
I used third order polynomials in theta and second order polynomials in x to reconstruct delta.
Tg_dp calibration:
I want to include deuterium elastic runs into my optics matrix calibration. In order to do so, I need to isolate elastic deuterons from elastic protons. I am trying to do this by applying different cuts on dE/E plots. Here are the results of this procedure for different runs:
Details on the dE/E cut determination are here (Mathematica): EdEManipulation.pdf
Details on the delta matrix element determination are here (Mathematica): fit5.pdf
#2167 - Deuteron Elastic run with (pc=0.38GeV/c) with all cuts:
#2164 - Deuteron Elastic run with (pc=0.5GeV/c) with all cuts
#2164 - Deuteron Elastic run with (pc=0.5GeV/c) with dE/E-cuts only
#2294 - Deuteron production run with (pc=0.5GeV/c) with dE/E-cuts only
#1518 - Hydrogen elastic run with (pc=0.5GeV/c) with dE/E-cuts only
#3488 - Proton Elastic run with (pc=0.5GeV/c) with dE/E-cuts only
Last Modified: 11/22/09