Meeting No. 19

Systematics of the Rad-Cut-Off parameter

I have investigated how the change of the rad-cut-f parameter changes the results. This cut that we are using is in principle not simple and brings with several potential consequences. I have changed the parameter for an order of magniuture up and down. After the renormalization of the slope the results for less than what we can observe. Hence, I dedided to say that the uncertainty is smaller than 0.1%. The plot below shows the results of the analysis. For the comparision plot also shows the results obtained with the latest polynomial fit and not Bernauer parameterization.

01.)

Results:

Here are my latest results. I removed elastic points from the plot. I suggest the following plot for the paper. The comparison between the data and simulation is still done with Bernauer parameterization.

02.)

Here is the latest GEp plot. The two errorbars shows the statistical and statistical+systematical uncertainties. The Bernauer results are shown with data points extracted from XS data to ilustrate the reach in Q**2. Is this OK?

. 03.)

The radius is: [ 0.8405 +/- (0.0196)stat +/- (0.0276)syst +/- (0.003)model ] fm

To-Do:

Redo the analysis with our best fit instead of bernauer results and make independent plot with results!
Last modified on 16/09/2016